Sunday, 1 November 2026

Various Updates and New Layout Planning

I went on a bit of a splurge recently buying up rolling stock, mostly used for the eventual big railway. Some people would probably say that's foolish, but I'm happy to get it done. It's all in the era that I enjoy and I can't see myself buying much else. Covering the basics at least.

Essentially I now have enough rolling stock for the 20 odd locos I have to all pull a decent prototypical-ish train. I've got a few bits still on preorder (Dapol Blue Spot Fish Vans, Dapol Stanier Suburban Coaches, Dapol Gresley BG and refurbished Buffet Coaches, Dapol Ivatt Push Pull, Dapol 63xx) and I'm also considering preordering the EFE Rail Baby Deltic... partly as a result of some recent future layout planning.

A while ago I came across an ingenious 3/4 point plan for Minories posting by a user on RMWeb which inspired me to draw up a few different layouts which culminated in the below - 

 

Which took the 4 point plan and added a further 2 points to make a busier terminus with dedicated parcels platform and carriage/relief siding.

That got filed away for a number of months whilst I worked on other things... but then I noticed yesterday that British Finescale where having a Halloween 20% off discount and it got my grey matter going again. You may remember my small DCC test track which currently sits in front of my PC monitor connected to JMRI for programming purposes.

Originally the plans above where done in both Code 40 and Peco Code 55 - and the price difference was a wash (ignoring my time building Code 40 of course). At the moment double slips and single slips are more expensive on Ebay than buying from a model shop!

The main problem with Peco Code 55 is the flange way spacing - to ensure backwards compatibility with older rolling stock, the gaps and depth are huge. Even on medium electrofrogs rolling stock drops and jerks about rolling across. The slips are even worse for this! That for me rules out using Peco anywhere except the fiddleyard/non-scenic areas which is annoying. Their Code 80 points are actually better performers in this regard as they don't need to drop as much due to the visible rail height being greater - but sadly, no 3 way or slips available in that range.

The other factor in deciding to go with Code 40 is that it is a project in itself, building each kit - and lets me gain more experience ahead of building a bigger layout. I know some people would rule it out purely on the basis of life being too short to build your own track - but I think that's missing the point and compromising too much.

So a threeway point, doubleslip, singleslip, right hand B6 and some flex track lengths have been ordered. It wouldn't let me order the full quantity I need but I can order some more at a later date anyway as they didn't have the rail joiners in stock. I also want to mix in some flat bottomed track sections with the bullhead. 

The plan I'm intending to build is stripped back to the original which was posted on RMWeb and will replace the OO layout I currently have on my shelf.

 

The fiddleyard will be a traverser with 75cm long tracks which will accommodate loco + 3/4 coaches comfortably. Currently in two minds whether to elevate the trackplan on a viaduct, or leave it and have a cutting/retaining wall behind. Control will be DCC to make life a bit easier. 

I'll probably build the point kits first before moving onto constructing new baseboards/traverser - but that should keep me occupied and stop me from buying stuff!

In other news, the variable power supply arrived for the branch line layout but I haven't fitted it yet. I'm actually considering whether that layout and rolling stock would benefit from going DCC as well. As a small branchline terminus with short wheelbase rolling stock, the choice of Peco setrack was perhaps a poor one. At the correct operating speeds, the chance of them stalling is pretty high. 

I'll do some experimenting with both modes of control and see if I think DCC with stayalives for the 3MT and Pannier is the way to go.

Still haven't made a start on the scenics... but I did solve a track issue. 

This section here before the station where one of the track feeds is had a slight dip - this results in some locos experiencing wheelslip, and my Mk1 Suburbans derailing before/after. I had to remove the ballast, slip in some cardboard strips to elevate it slightly and reballast but it appears to have cured the problems so far.
 

No comments:

Post a Comment